Please note that the copy function is not enabled for this field.
If you wish to
modify
existing outcomes, please copy and paste the current outcome text into the Update field.
LOGIN
CREATE ACCOUNT
LOGIN
CREATE ACCOUNT
MY TRIALS
REGISTER TRIAL
FAQs
HINTS AND TIPS
DEFINITIONS
Trial Review
The ANZCTR website will be unavailable from 1pm until 3pm (AEDT) on Wednesday the 30th of October for website maintenance. Please be sure to log out of the system in order to avoid any loss of data.
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been endorsed by the ANZCTR. Before participating in a study, talk to your health care provider and refer to this
information for consumers
Download to PDF
Trial registered on ANZCTR
Registration number
ACTRN12619000849190p
Ethics application status
Submitted, not yet approved
Date submitted
17/05/2019
Date registered
14/06/2019
Date last updated
14/06/2019
Date data sharing statement initially provided
14/06/2019
Type of registration
Prospectively registered
Titles & IDs
Public title
What does open eye lens centration tell us about the treatment zone centration after overnight wear of orthokeratology (OK) lenses?
Query!
Scientific title
What does open eye lens centration tell us about the treatment zone centration after overnight wear of orthokeratology (OK) lenses in eyes with Myopia?
Query!
Secondary ID [1]
298262
0
None
Query!
Universal Trial Number (UTN)
Query!
Trial acronym
Query!
Linked study record
Query!
Health condition
Health condition(s) or problem(s) studied:
Myopia
312870
0
Query!
Condition category
Condition code
Eye
311368
311368
0
0
Query!
Diseases / disorders of the eye
Query!
Intervention/exposure
Study type
Interventional
Query!
Description of intervention(s) / exposure
Description of intervention: BE Orthokeratology contact lenses (Capricornia Contact Lens, Brisbane, Australia) in Boston XO material with 100 Dk units ISO/Fatt are used in this study. This is one of the most common materials used for conventional orthokeratology in Australia and abroad.
Exposure: Study lenses are worn overnight during sleep (for minimum of 7-8 hours) over a period of 3 nights with no need for day time lens wear.
Delivery: The research team will initially insert the lens on the subject's eye at the School of Optometry and Vision Science, UNSW, Sydney. Research participants will then be taught one-on-one face-to-face how to insert, remove, clean and maintain orthokeratology lenses so that subjects can safely wear contact lenses during the trial period.
Adherence to the study protocol will be ensured by investigation team advising participants to complete a "Ortho-K Wear Time Journal” to record your OK lens insertion and removal times as well as sleep and waking up times.
Query!
Intervention code [1]
314509
0
Treatment: Devices
Query!
Comparator / control treatment
Description of intervention: BE Orthokeratology contact lenses (Capricornia Contact Lens, Brisbane, Australia) in Boston XO material with 100 Dk units ISO/Fatt are used in this study. This is one of the most common materials used for conventional orthokeratology in Australia and abroad.
Exposure: Study lenses are worn for a about half hour during open eye conidtion at the research facility at the time of dispensing and then worn overnight during sleep (for minimum of 7-8 hours) over a period of 3 nights with no need for day time lens wear.
Delivery: The research team will initially insert the lens on the subject's eye at the School of Optometry and Vision Science, UNSW, Sydney. Research participants will then be taught one-on-one face-to-face how to insert, remove, clean and maintain orthokeratology lenses so that subjects can safely wear contact lenses during the trial period.
Adherence to the study protocol will be ensured by investigation team advising participants to complete a "Ortho-K Wear Time Journal” to record your OK lens insertion and removal times as well as sleep and waking up times.
Comparator is 'no treatment' situation therefore the lens centration and treatment zone decentration after the open eye and closed eye situations respectively are compared to zero (no treatment). The open eye lens decentration recorded at the time of lens dispensing and compared to zero (no treatment) and the overnight treatment zone parameters are also compared to zero (no treatment). The amount of open eye lens decentration and the treatment zone decentration after overnight wear are also compared.
Query!
Control group
Active
Query!
Outcomes
Primary outcome [1]
320096
0
The open eye lens decentration recorded at the time of lens dispensing and compared to zero (no treatment)
The open eye decentration is measured using a custom designed software (i-Metrics) from the eye videos captured at the time of lens dispensing. The software allows the user to trace the decentred lens position on the captured video, thus determining the amount of decentration in open eye condition from zero (no treatment)
Query!
Assessment method [1]
320096
0
Query!
Timepoint [1]
320096
0
At baseline.
Study (lens decentration) measurements will be determined from the digital videos captured within 15-20 minutes after lens insertion at baseline.
Query!
Primary outcome [2]
320176
0
The closed eye treatment zone decentration recorded after one night and three nights of wear is compared to zero (no treatment)
Study (treatment zone decentration) measurements will be determined from the corneal topography images captured after one night and three nights of lens wear. A custom written software program developed at the University of New South Wales allows the investigator to delineate the treatment zone from the coloured topography maps captured at these time points thus determining the amount of treatment zone decentration from zero (no treatment)
Query!
Assessment method [2]
320176
0
Query!
Timepoint [2]
320176
0
one and three nights of wear.
Query!
Secondary outcome [1]
370529
0
Eyelid morphometry features (including palpebral fissure height, position of eyelids relative to limbus, eyelid slant etc) are assessed using the i-Metrics software. Assessing Eyelid morphometry features is an exploratory composite secondary outcome. The investigator uploads the images (derived from the digital videos) of the anterior eye captured at the first visit into the software. The investigator then draws the outline of upper and lower eyelids, limbus, pupil etc. The software then calculates the relative distances between each of the outlined features.
Query!
Assessment method [1]
370529
0
Query!
Timepoint [1]
370529
0
First study visit (baseline)
Query!
Eligibility
Key inclusion criteria
• Males and females over 18 years of age
• Good ocular and general health
• Refractive error -1.00D to -6.00D and corneal toricity (astigmatism) <1.50D
• Anisometropia (difference spectacle power between the two eyes) <1.00D
Query!
Minimum age
18
Years
Query!
Query!
Maximum age
40
Years
Query!
Query!
Sex
Both males and females
Query!
Can healthy volunteers participate?
No
Query!
Key exclusion criteria
• Any previous rigid gas permeable, including orthokeratology lens wearers
• Soft contact lens wear in the past week
• Contraindications to rigid lens wear, including orthokeratology lens wearers
Query!
Study design
Purpose of the study
Treatment
Query!
Allocation to intervention
Randomised controlled trial
Query!
Procedure for enrolling a subject and allocating the treatment (allocation concealment procedures)
Query!
Methods used to generate the sequence in which subjects will be randomised (sequence generation)
Query!
Masking / blinding
Query!
Who is / are masked / blinded?
Query!
Query!
Query!
Query!
Intervention assignment
Query!
Other design features
Query!
Phase
Not Applicable
Query!
Type of endpoint/s
Query!
Statistical methods / analysis
Query!
Recruitment
Recruitment status
Not yet recruiting
Query!
Date of first participant enrolment
Anticipated
1/07/2019
Query!
Actual
Query!
Date of last participant enrolment
Anticipated
30/11/2020
Query!
Actual
Query!
Date of last data collection
Anticipated
31/12/2020
Query!
Actual
Query!
Sample size
Target
13
Query!
Accrual to date
Query!
Final
Query!
Recruitment in Australia
Recruitment state(s)
NSW
Query!
Funding & Sponsors
Funding source category [1]
302807
0
University
Query!
Name [1]
302807
0
University of New South Wales
Query!
Address [1]
302807
0
School of Optometry and Vision Science Rupert Myer Building (North Wing) University of New South Wales
Gate 14, Barker Street Kensington, NSW 2033
Query!
Country [1]
302807
0
Australia
Query!
Primary sponsor type
University
Query!
Name
University of New South Wales
Query!
Address
School of Optometry and Vision Science Rupert Myer Building (North Wing) University of New South Wales
Gate 14, Barker Street Kensington, NSW 2033
Query!
Country
Australia
Query!
Secondary sponsor category [1]
302753
0
None
Query!
Name [1]
302753
0
Query!
Address [1]
302753
0
Query!
Country [1]
302753
0
Query!
Ethics approval
Ethics application status
Submitted, not yet approved
Query!
Ethics committee name [1]
303391
0
UNSW Human Research Ethics Advisory Panel
Query!
Ethics committee address [1]
303391
0
UNSW Research Ethics & Compliance Support Rupert Myer Building (South Wing) University of New South Wales Gate 14, Barker Street Kensington, NSW 2033
Query!
Ethics committee country [1]
303391
0
Australia
Query!
Date submitted for ethics approval [1]
303391
0
20/05/2019
Query!
Approval date [1]
303391
0
Query!
Ethics approval number [1]
303391
0
Query!
Summary
Brief summary
Orthokeratology (OK) lenses are rigid contact lenses that are designed to be worn during sleep. Their purpose is to reshape the front surface of the eye (cornea) in order to temporarily correct short- sightedness, also known as myopia. Although their primary aim is to correct myopia and provide clear unaided vision during the day, studies have shown that they also have an effect on slowing or stopping the progression of short-sightedness in children, termed myopia control. Currently, research is underway to understand centration of OK lenses and the optical effects as a result of centration which may promote myopia control. Although optometrists will typically assess the centration of the lens in the open eye, it is not clear how much this influences treatment zone centration after overnight wear in the closed eye, and this warrants investigation. The aim of this project is to compare open eye lens centration with treatment zone centration after 3 nights of overnight wear of OK lenses. We will investigate open eye lens centration with and without eyelid interactions, as well as lens centration immediately after eye opening following short-term eye closure. Our intent is to determine how these measurements can be used clinically to predict treatment zone centration after overnight OK lens wear.
Query!
Trial website
Query!
Trial related presentations / publications
Query!
Public notes
Query!
Contacts
Principal investigator
Name
93514
0
Dr Vinod Maseedupally
Query!
Address
93514
0
School of Optometry and Vision Science
University of New South Wales
Gate 14, Barker Street Kensington, NSW 2033
Query!
Country
93514
0
Australia
Query!
Phone
93514
0
+61 2 9385 9233
Query!
Fax
93514
0
Query!
Email
93514
0
[email protected]
Query!
Contact person for public queries
Name
93515
0
Vinod Maseedupally
Query!
Address
93515
0
School of Optometry and Vision Science
University of New South Wales
Gate 14, Barker Street Kensington, NSW 2033
Query!
Country
93515
0
Australia
Query!
Phone
93515
0
+61 2 9385 9233
Query!
Fax
93515
0
Query!
Email
93515
0
[email protected]
Query!
Contact person for scientific queries
Name
93516
0
Vinod Maseedupally
Query!
Address
93516
0
School of Optometry and Vision Science
University of New South Wales
Gate 14, Barker Street Kensington, NSW 2033
Query!
Country
93516
0
Australia
Query!
Phone
93516
0
+61 2 9385 9233
Query!
Fax
93516
0
Query!
Email
93516
0
[email protected]
Query!
Data sharing statement
Will individual participant data (IPD) for this trial be available (including data dictionaries)?
No
Query!
No/undecided IPD sharing reason/comment
Query!
What supporting documents are/will be available?
No Supporting Document Provided
Results publications and other study-related documents
Documents added manually
No documents have been uploaded by study researchers.
Documents added automatically
No additional documents have been identified.
Download to PDF